数量阶梯 | 香港交货 | 国内含税 |
+xxxx | $xxxx | ¥xxxx |
查看当月历史价格
查看今年历史价格
LV 25-P产品简介:
ICGOO电子元器件商城为您提供LV 25-P由LEM设计生产,在icgoo商城现货销售,并且可以通过原厂、代理商等渠道进行代购。 LV 25-P价格参考¥288.55-¥288.55。LEMLV 25-P封装/规格:专用传感器, Voltage, Closed Loop Sensor Voltage Output。您可以下载LV 25-P参考资料、Datasheet数据手册功能说明书,资料中有LV 25-P 详细功能的应用电路图电压和使用方法及教程。
参数 | 数值 |
产品目录 | |
描述 | TRANSDUCR VOLTAG CLOSE LOOP 10MA |
产品分类 | |
品牌 | LEM USA Inc |
数据手册 | |
产品图片 | |
产品型号 | LV 25-P |
rohs | 无铅 / 符合限制有害物质指令(RoHS)规范要求 |
产品系列 | LV |
产品目录绘图 | |
产品目录页面 | |
传感器类型 | 电压,闭环 |
其它名称 | 398-1019 |
标准包装 | 1 |
输出类型 | 电压 |
Voltage Transducer LV 25-P I = 10 mA PN For the electronic measurement of currents: DC, AC, pulsed..., V = 10 .. 500 V with galvanic separation between the primary circuit and the secondary PN circuit. HV HV Electrical data Features I Primary nominal rms current 10 mA ● Closed loop (compensated) PN I Primary current, measuring range 0 .. ± 14 mA current transducer using the Hall PM R Measuring resistance R R effect M M min M max with ± 12 V @ ± 10 mA 30 190 Ω ● Insulating plastic case recognized max @ ± 14 mA 30 100 Ω according to UL 94-V0. max with ± 15 V @ ± 10 mA 100 350 Ω max Principle of use @ ± 14 mA 100 190 Ω max ISN Secondary nominal rms current 25 mA ● For voltage measurements, KN Conversion ratio 2500 : 1000 a current proportional to the UC Supply voltage (± 5 %) ± 12 .. 15 V measured voltage must be IC Current consumption 10 (@ ± 15 V) + IS mA passed through an external resistor R which is selected by Accuracy - Dynamic performance data 1 the user and installed in series with the primary circuit of the X Overall accuracy @ I , T = 25 °C @ ± 12 .. 15 V ± 0.9 % G PN A transducer. @ ± 15 V (± 5 %) ± 0.8 % εL Linearity error < 0d.C2l %dCp Advantages Typ Max R 1 I Offset current @ I = 0, T = 25 °C ± 0.15 mA ● Excellent accuracy HV O P A I Temperature variation of I 0 °C .. + 25 °C ± 0.06 ± 0.25 mA ● Very good linearity HV OT O U + 25 °C .. + 70 °C ± 0.10 ± 0.35 mA ● Low thermal drift C tr IS SteRpM response time 1) to 90 % of IPN 40 µs ● Low response time ● High bandwidth General dataU ● High immunity to external C interference T Ambient operating temperature 0 .. + 70 °C A ● Low disturbance in common T Ambient storage temperature - 25 .. + 85 °C S mode. R Resistance of primary winding @ T = 70 °C 250 Ω P A R Resistance of secondary winding @ T = 70 °C 110 Ω Applications S A m Mass 22 g Standards EN 50178: 1997 ● AC variable speed drives and UL 508: 2010 servo motor drives ● Static converters for DC motor drives ● Battery supplied applications ● Uninterruptible Power Supplies Note: 1) R = 25 kΩ (L/R constant, produced by the resistance and inductance of 1 (UPS) the primary circuit). ● Power supplies for welding applications. Application domain ● Industrial. N° 97.27.19.000.0 Page 1/4 12August2014/version 19 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com
Voltage Transducer LV 25-P Insulation coordination U Rms voltage for AC insulation test, 50 Hz, 1 min 2.5 1) kV d Û Impulse withstand voltage 1.2/50 µs 16 kV W Min d Creepage distance 19.5 mm Cp d Clearance 19.5 mm CI CTI Comparative tracking index (group IIIa) 175 Note: 1) Between primary and secondary. Applications examples According to EN 50178 and IEC 61010-1 standards and following conditions: ● Over voltage category OV 3 ● Pollution degree PD2 ● Non-uniform field EN 50178 IEC 61010-1 d , d , Û Rated insulation voltage Nominal voltage Cp CI W Basic insulation 1600 V 1600 V Reinforced insulation 800 V 800 V Safety This transducer must be used in limited-energy secondary circuits according to IEC 61010-1. This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/4 12August2014/version 19 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com
UL 508:Ratings and assumptions of certification File # E189713 Volume: 2 Section: 1 Standards ● CSA C22.2 NO. 14 - 10 INDUSTRIAL CONTROL EQUIPMENT - Edition 11 - Revision Date 2011/08/01 ● UL 508 STANDARD FOR INDUSTRIAL CONTROL EQUIPMENT - Edition 17 - Revision Date 2010/04/15. Parameter Symbol Unit Value Primary involved potential V AC/DC 600 Max surrounding air temperature T °C 85 A Primary current I mA 0 to 10 P Secondary supply voltage U V DC ± 12 to ±15 C Secondary nominal rms current I mA 25 SN Conditions of acceptability When installed in the end-use equiment, consideration shall be given to the following: 1 - These devices must be mounted in a suitable end-use enclosure. 2 - The terminals have not been evaluated for field wiring. 3 - The LV 25-P series are intended to be mounted on the printed wiring board of the end-use equipment (with a minimum CTI of 100). 4 - The LV 25-P series shall be used in a pollution degree 2 environment when the Printed Wiring Board has not been coated. 5 - The LV 25-P series shall be mounted on the load side of line filters. 6 - Low voltage circuits are intended to be powered by a circuit derived from an isolating source (such as a transformer,optical isolator,limiting impedance or electro-mechanical relay) and having no direct connection back to the primary circuit (other than through the grounding means). 7 - Base on results of temperature tests, int he end use application, a maximum of 100 °C cannot be exceeded at soldering point between primary coil pin and soldering point of on the primary bus bar (corrected to the appropriate evaludated max. surrounding air). Marking Only those products bearing the UL or UR Mark should be considered to be Listed or Recognized and covered under UL’s Follow-Up Service.Always look for the Mark on the product. Page 3/4 12August2014/version 19 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com
Dimensions LV 25-P (in mm) HV HV HV HV HV HV HV HV d d Cl Cp HV R1 dCl dCp R HV 1 U d HV d I R C Cl Cp S M HV R U HV 1 I R C UC HV S M U C I R S M U C Mechanical characteristics Remarks U d d C Cl Cp ● General tolerance ± 0.2 mm ● I is positive when V is applied on terminal + HV. ● FasteningH V& cRo1nnection of primary 2 pins ● InSstallation of the tranPsducer must be done unless HV 0.635 × 0.635 mm otherwise specified on the datasheet, according to LEM U C ● Fastening & connection of secondaryI 3 piRns Ø 1 mm Transducer Generic Mounting Rules. Please refer to S M ● Recommended PCB hole Ø 1.2 mm LEM document N°ANE120504 available on our Web site: U C Products/Product Documentation. ● This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. Instructions for use of the voltage transducer model LV 25-P Primary resistor R: the transducer’s optimum accuracy is obtained at the nominal primary current. As far as possible, R should 1 1 be calculated so that the nominal voltage to be measured corresponds to a primary current of 10 mA. Example: Voltage to be measured V = 250 V a) R = 25 kΩ / 2.5 W, I = 10 mA Accuracy = ± 0.9 % of V (@ T = + 25 °C) PN 1 P PN A b) R = 50 kΩ / 1.25 W, I = 5 mA Accuracy = ± 1.5 % of V (@ T = + 25 °C) 1 P PN A Operating range (recommended): taking into account the resistance of the primary windings (which must remain low compared to R, in order to keep thermal deviation as low as possible) and the insulation, this transducer is suitable for measuring nominal 1 voltages from 10 to 500 V. Page 4/4 12August2014/version 19 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com